ETFOptimize | High-performance ETF-based Investment Strategies

Quantitative strategies, Wall Street-caliber research, and insightful market analysis since 1998.


ETFOptimize | HOME
Close Window

GE HealthCare’s growing list of medical institutions conducting human subject research studies with its novel photon counting CTi technology further expands with the addition of Stanford Medicine

  • Unique from current CT technology, GE HealthCare’s proprietary photon counting CT design is engineered to leverage Deep Silicon detectors with the goal of capturing more patient data for clearer images and detailed information to help inform diagnoses across care areas
  • Researchers at Stanford Medicine will collaborate with GE HealthCare for the intended future benefit of clinicians and patients – scanning human subjects on a prototype system as part of a research study to assess the developing technology and provide helpful insights for its evolution

As part of a research study, researchers at Stanford Medicine, Department of Radiology recently began scanning human subjects on GE HealthCare’s novel photon counting CT prototype designed with Deep Silicon detectors,i,ii which aims to greatly enhance imaging capabilities and provide clinicians the information and data they need to help enable improved patient outcomes across oncology, cardiology, neurology, and other clinical CT applications.

Photon counting CT technology has the potential to further improve the capabilities of traditional CT, including the visualization of minute details of organ structures, improved tissue characterization, more accurate material density measurement (or quantification), and lower radiation dose. Altogether, it has the promise to be a substantial step forward for CT imaging that can potentially benefit millions of patients worldwide.

“As a CT researcher, it is especially exciting to see this new advancement in CT technology,” shares David Larson, MD, MBA, Executive Vice Chair, Department of Radiology, Stanford Medicine.iii “Since its invention 50 years ago, CT has become a major workhorse in medical imaging across the world. Photon counting technology marks what is probably the most significant technological advancement in CT in more than a decade, and perhaps longer.”

Stanford Medicine researchers will facilitate human subject research and produce technical feedback to test and help advance GE HealthCare’s photon counting CT technology with Deep Silicon. The study will assess reconstruction methods, image presentation workflows, and clinical benefits for specific pathologies and disease types to help optimize GE HealthCare’s patented technology to enable better visualization and utilization.

Achieving greater depth with Deep Silicon technology

From the first x-ray machines to the first silicon-based photon counting prototype, GE HealthCare is committed to pioneering next generation imaging technology. GEiv researchers began studying photon counting CT in 1993 and developed the world’s first photon counting CT prototype using cadmium-based detectors in 2006.

After three decades of research and development, GE HealthCare has chosen Deep Silicon as the semiconductor material of choice for its photon counting CT detector due to its potential to deliver outstanding spatial resolution without compromising count rate or spectral resolution – all with the goal of helping clinicians’ realize the full potential of spectral CT.

As a semi-conductor material, silicon has a number of advantages including its purity, abundance, and broad manufacturing infrastructure. Historically, the main challenge with the use of silicon as a detector material is that it is too thin to stop and collect a sufficient number of x-ray photons. GE HealthCare has overcome this challenge with a patented, novel approach, positioning the silicon sensors ‘edge on’ so the detector is deep enough to absorb very high energy photons and fast enough to count and quantify the energies of hundreds of millions of x-ray photons per second. This way, the effective depth of the detector is determined not by the thickness of the silicon, but by its length – allowing the detector to have as long an absorption length as necessary. This is why it is called “Deep Silicon.”

“The installation of this GE HealthCare prototype marks our first photon counting CT scanner, and first whole-body scanner at the Stanford Research Park, where our research activities continue to grow,” explains Adam Wang, PhD, Assistant Professor, Department of Radiology and, by courtesy, Electrical Engineering, Stanford University.iii

The prototype installation at Stanford Medicine comes less than a year after GE HealthCare announced its first U.S. clinical evaluation site at the University of Wisconsin–Madison and two years after the establishment of its first global site with Karolinska Institutet and MedTechLabs in Sweden.

“The collaborative spirit shared by Stanford Medicine, UW—Madison, Karolinska Institutet, MedTechLabs, and our GE HealthCare team defines our institutions and is foundational to the success we are seeing with photon counting CT technology utilizing Deep Silicon detectors,” reflects Jean-Luc Procaccini, President and CEO, Molecular Imaging & Computed Tomography, GE HealthCare. “We are thrilled to work with Stanford Medicine’s team of seasoned researchers and clinicians as we continue to evolve this cutting-edge technology based on the valuable insights they and all our collaborators provide. Together, we are making giant leaps forward in what we expect will be a breakthrough in CT technology for the next several decades.”

For more information on GE HealthCare’s unique approach to photon counting CT with deep silicon detectors, visit gehealthcare.com.

i Technology in development that represents ongoing research and development efforts. These technologies are not products and may never become products. Not for sale. Not cleared or approved by the U.S. FDA or any other global regulator for commercial availability. Not CE marked.

ii The study is being conducted with the approval of the Institutional Review Boards.

iii The statements by GE HealthCare’s customers described here are based on their own opinions and on results that were achieved in the customer’s unique setting. Since there is no “typical” hospital and many variables exist, i.e. hospital size, case mix, etc.. there can be no guarantee that other customers will achieve the same results.

iv A trademark of General Electric Corporation.

Contacts

GE HealthCare Media Contact:

Margaret Steinhafel

Global Communications Director, Molecular Imaging & Computed Tomography

M +1 608 381 8829

margaret.steinhafel@ge.com

Recent Quotes

View More
Symbol Price Change (%)
AMZN  229.16
-0.51 (-0.22%)
AAPL  277.55
+0.58 (0.21%)
AMD  214.24
+8.11 (3.93%)
BAC  52.99
+0.51 (0.97%)
GOOG  320.28
-3.36 (-1.04%)
META  633.61
-2.61 (-0.41%)
MSFT  485.50
+8.51 (1.78%)
NVDA  180.26
+2.44 (1.37%)
ORCL  204.96
+7.93 (4.02%)
TSLA  426.58
+7.18 (1.71%)
Stock Quote API & Stock News API supplied by www.cloudquote.io
Quotes delayed at least 20 minutes.
By accessing this page, you agree to the Privacy Policy and Terms Of Service.


 

IntelligentValue Home
Close Window

DISCLAIMER

All content herein is issued solely for informational purposes and is not to be construed as an offer to sell or the solicitation of an offer to buy, nor should it be interpreted as a recommendation to buy, hold or sell (short or otherwise) any security.  All opinions, analyses, and information included herein are based on sources believed to be reliable, but no representation or warranty of any kind, expressed or implied, is made including but not limited to any representation or warranty concerning accuracy, completeness, correctness, timeliness or appropriateness. We undertake no obligation to update such opinions, analysis or information. You should independently verify all information contained on this website. Some information is based on analysis of past performance or hypothetical performance results, which have inherent limitations. We make no representation that any particular equity or strategy will or is likely to achieve profits or losses similar to those shown. Shareholders, employees, writers, contractors, and affiliates associated with ETFOptimize.com may have ownership positions in the securities that are mentioned. If you are not sure if ETFs, algorithmic investing, or a particular investment is right for you, you are urged to consult with a Registered Investment Advisor (RIA). Neither this website nor anyone associated with producing its content are Registered Investment Advisors, and no attempt is made herein to substitute for personalized, professional investment advice. Neither ETFOptimize.com, Global Alpha Investments, Inc., nor its employees, service providers, associates, or affiliates are responsible for any investment losses you may incur as a result of using the information provided herein. Remember that past investment returns may not be indicative of future returns.

Copyright © 1998-2017 ETFOptimize.com, a publication of Optimized Investments, Inc. All rights reserved.